PT - JOURNAL ARTICLE AU - Sanghun Choi AU - Babak Haghighi AU - Jiwoong Choi AU - Eric A Hoffman AU - Alejandro P Comellas AU - John D Newell AU - Sally E Wenzel AU - Mario Castro AU - Sean B Fain AU - Nizar N Jarjour AU - Mark L Schiebler AU - R Graham Barr AU - MeiLan K Han AU - Eugene R Bleecker AU - Christopher B Cooper AU - David Couper AU - Nadia Hansel AU - Richard E Kanner AU - Ella A Kazerooni AU - Eric A C Kleerup AU - Fernando J Martinez AU - Wanda K O’Neal AU - Prescott G Woodruff AU - Ching-Long Lin ED - , TI - Differentiation of quantitative CT imaging phenotypes in asthma versus COPD AID - 10.1136/bmjresp-2017-000252 DP - 2017 Nov 01 TA - BMJ Open Respiratory Research PG - e000252 VI - 4 IP - 1 4099 - http://bmjopenrespres.bmj.com/content/4/1/e000252.short 4100 - http://bmjopenrespres.bmj.com/content/4/1/e000252.full SO - BMJ Open Resp Res2017 Nov 01; 4 AB - Introduction Quantitative CT (QCT) imaging-based metrics have quantified disease alterations in asthma and chronic obstructive pulmonary disease (COPD), respectively. We seek to characterise the similarity and disparity between these groups using QCT-derived airway and parenchymal metrics.Methods Asthma and COPD subjects (former-smoker status) were selected with a criterion of post-bronchodilator FEV1 <80%. Healthy non-smokers were included as a control group. Inspiratory and expiratory QCT images of 75 asthmatic, 215 COPD and 94 healthy subjects were evaluated. We compared three segmental variables: airway circularity, normalised wall thickness and normalised hydraulic diameter, indicating heterogeneous airway shape, wall thickening and luminal narrowing, respectively. Using an image registration, we also computed six lobar variables including per cent functional small-airway disease, per cent emphysema, tissue fraction at inspiration, fractional-air-volume change, Jacobian and functional metric characterising anisotropic deformation.Results Compared with healthy subjects, both asthma and COPD subjects demonstrated a decreased airway circularity especially in large and upper lobar airways, and a decreased normalised hydraulic diameter in segmental airways. Besides, COPD subjects had more severe emphysema and small-airway disease, as well as smaller regional tissue fraction and lung deformation, compared with asthmatic subjects. The difference of emphysema, small-airway disease and tissue fraction between asthma and COPD was more prominent in upper and middle lobes.Conclusions Patients with asthma and COPD, with a persistent FEV1 <80%, demonstrated similar alterations in airway geometry compared with controls, but different degrees of alterations in parenchymal regions. Density-based metrics measured at upper and middle lobes were found to be discriminant variables between patients with asthma and COPD.